Outputting Data and Controlling Operation through EtherNet/IP
FQ2 User’s Manual
303
C
onne
cti
ng th
rough
Ethern
et
9
• Output Area
The output area is assigned immediately after the response area in I/O memory.
Bits
Contents
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
+8
DATA 0
Output data
0 (32 bits)
+9
·
·
·
·
·
·
·
·
·
+22
DATA 7
Output data
7 (32 bits)
+23
·
·
·
·
·
·
·
·
·
+38
DATA 15
Output data
15 (32 bits)
+39
·
·
·
·
·
·
·
·
·
+70
DATA 31
Output data
31 (32 bits)
+71
·
·
·
·
·
·
·
·
·
+134
DATA 63
Output data
63 (32 bits)
+135
Signal
Signal name
Function
Application
DATA0-63
Output data 0 to 63
These I/O ports output the output data that is
specified for the data output method.
The data that can be output is determined by
the set value of the Output data size setting as
follows:
32 bytes: Output data 0 to 7
64 bytes: Output data 0 to 15
128 bytes: Output data 0 to 31
256 bytes: Output data 0 to 63
Command/
response commu-
nications
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......