Outputting Data and Controlling Operation through EtherNet/IP
FQ2 User’s Manual
291
C
onne
cti
ng th
rough
Ethern
et
9
Timeout
This parameter is displayed and can be set only
when [Handshake setting] is set to [Yes].
A timeout error will occur if there is no response
from the PLC within the time that is set.
• From when measurements are completed
until the DSA Bit turns ON
• From when the GATE flag turns ON until the
DSA Bit turns OFF
• From when the GATE flag turns OFF until the
DSA Bit turns ON
0.1 to 120.0 s (default: 10 s)
Data output period This parameter is displayed and can be set only
when [Handshake setting] is set to [No]. Set the
period for outputting measurement results.
Set a value that is longer that the GATE ON
output time and shorter than the measurement
interval of the Sensor.
2 to 5,000 ms (default: 40 ms)
GATE signal ON
period
This parameter is displayed and can be set only
when [Handshake setting] is set to [No].
Set the time to turn ON the GATE signal.
Set the time that is required for the PLC to read
the measurement results.
Set the cycle time of the PLC so that it is longer
than the packet interval (RPI).
1.0 to 1,000.0 ms (default: 20.0 ms)
Parameter
Description
Setting range
Important
Important
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......