![background image](http://html1.mh-extra.com/html/omron/fq2-series/fq2-series_user-manual_742876389.webp)
Controlling Operation and Outputting Data with FINS/TCP No-protocol Commands
FQ2 User’s Manual
387
C
onne
cti
ng th
rough
Ethern
et
9
Getting the Inspection Item Data: 280F 00401020
This command acquires the parameters and measurement values of the specified inspection item.
●
Format
●
Response Format
●
End Codes
●
Parameter Descriptions
MRC
(1 byte)
SRC
(1 byte)
Vision Sensor command code
(4 bytes)
Inspection item number (4 bytes) External reference
number (4 bytes)
28
0F
00401020
Inspection item number from 00
to 1F (2 digits max.)
External reference
number
MRC
(1 byte)
SRC
(1 byte)
MRES
(1 byte)
SRES
(1 byte)
Vision Sensor command code
(4 bytes)
Acquired value (4
bytes)
28
0F
End code
00401020
Acquired value
(1,000 times the
actual value)
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Inspection item number
Specifies the number of the inspection item for which to acquire the data.
External reference num-
ber
Specifies the external reference number.
12-2 External Reference Parameters: p. 430
Acquired value
Returns the data for the specified inspection item.
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......