Changing the Scene to Change the Line Process
190
FQ2 User’s Manual
7-1 Changing the Scene to Change the Line Process
What Are Scenes?
With an FQ2 Vision Sensor, the inspection items that can be processed at the same time are registered as
scenes. A command input from an external device or a touch panel operation can be used to select a certain
scene.
If a scene is registered for each type of measurement object or inspection, the line process can be changed
simply by changing the scene when the measurement object or inspection changes.
Example:
• Maximum Number of Scenes
• Settings Included with Scenes
The following settings are changed when the scene is changed: Camera image ([Image] Tab Page) and
Inspection Items ([Inspect] Tab Page). The settings related to external I/O specifications that are included in
the output settings and the system settings for the overall Sensor are used for all of the scenes.
Refer to the following information for the data that is included in the scene data.
Model
Item
Standard model (FQ2-S2/S3 Series)
Single-function model (FQ2-S1 Series)
Number of scenes
32
8
Inspection for
prod
u
ct A
Inspection for
prod
u
ct B
Inspection for
prod
u
ct C
Inspection for
prod
u
ct Z
Scene 1
Scene 2
Scene 0
Scene 31
Line Process Changes:
Text alignment
(Inspection item 2: Edge Position)
La
b
el detection
(Inspection item 1: Search)
These can
b
e registered as
one scene.
Cap color
(Inspection item 0: Color Data)
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......