Adjusting the Images That Were Taken
84
FQ2 User’s Manual
2
Press [Edge]
−
[2Edge midpoint comp.]
3
Make any detailed settings as required for the position compensation processing.
Refer to Detailed Settings for Two-edge Midpoint Compensation, below.
4
Press [OK].
5
Press [Back].
• Detailed Settings for Two-edge Midpoint Compensation
The settings for the Two-edge Midpoint Compensation item are almost the same as those for the Edge Position
inspection item.
Make the settings in the same way as for the Edge Position inspection item. (
Edge Position Inspection Item: p. 120)
However, the following settings are included only in the Edge Position Compensation Item.
• Teaching
Set the measurement regions and measurement directions for both edge 0 and edge 1.
[Image]
−
[Image adjustment]
−
[2Edge midpoint comp.]
−
[Modify]
−
[Basic]
−
[Teach]
The settings are the same as those for the Two-edge Position Compensation item.
• Source Image
You can select the image to which to apply the results of position compensation processing.
Applying the Results of Position Compensation: p. 75
• Interpolation
You can select the precision of position compensation.
If you select [Bilinear], the precision of position compensation will increase.
[Image]
−
[Image adjustment]
−
[2ed. midp. comp.]
−
[Modify]
−
[Details]
−
[Scroll parameter]
−
[Interpolation]
The settings are the same as those for the Shape Search Position Compensation item.
• Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via Ethernet or used in
calculations.
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG
DX
Scroll X
This is the amount of position com-
pensation for the X coordinate.
−
99,999.9999 to 99,999.9999
DY
Scroll Y
This is the amount of position com-
pensation for the Y coordinate.
−
99,999.9999 to 99,999.9999
X0
Edge 0 position X
This is the X coordinate of the mea-
sured edge 0 position.
−
99,999.9999 to 99,999.9999
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......