Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
FQ2 User’s Manual
273
8
Co
ntro
llin
g Operatio
n an
d Ou
tp
utti
ng Da
ta
with a Parall
el Con
nection
Input Signals to Change the Scene
Clearing Measurement Values
This command clears the measurement values.
Parameters
Timing Chart
Output Signals
Input Signals
Signal
Function
IN0 to IN4
These signals specify the scene number (0 to 31).
IN5
Turn ON.
IN6
Turn OFF.
IN7
This signal functions as the execution trigger. Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn ON the IN7
signal. The BUSY signal will be ON while the command is being executed.
Execution
Command
Input example
IN7
IN6
IN5
IN4
IN3
IN2
IN1
IN0
1
1000000
11000000
Signal
Function
RUN
This signal is ON while the Sensor is in Run Mode. It will be OFF in Setup Mode.
BUSY
This signal does not change while clearing measurement values.
ACK
When the command has been completed normally, this signal is turned ON for the time that is set for the ACK output time.
Signal
Function
IN0 to IN5 Turn OFF.
IN6
Turn ON.
IN7
This signal is the trigger for clearing measurement values. Set the IN0 to IN6 signals, wait for at least 5 ms, and then turn
ON the IN7 signal.
0
I
N
7 signal
OFF
O
N
OFF
O
N
RU
N
signal
OFF
O
N
I
N
0 to I
N
6
signals
R
u
n Mode entered.
Set
u
p Mode entered.
BUSY signal
11000000
Allo
w
5 ms min. and then t
u
rn O
N
I
N
7.
O
N
for 1 ms min.
ACK signal
OFF
O
N
ACK o
u
tp
u
t time
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......