Controlling Operation and Outputting Data with TCP No-protocol Communications
FQ2 User’s Manual
359
C
onne
cti
ng th
rough
Ethern
et
9
Command List
The following table lists the no-protocol commands.
Commands that can be used in no-protocol Ethernet communications are listed below.
Type of command
Command
Abbreviation
Function
Reference
Measurement control
and measurement acqui-
sition commands
MEASURE
M
Executes one measurement. p. 360
MEASURE /C
M /C
Starts continuous measure-
ments.
MEASURE /E
M /E
Ends continuous measure-
ments.
Utility commands
CLRMEAS
None
Clears the measurement val-
ues.
CLRERR
None
Clears the error output status
(error signal and error indica-
tor).
DATASAVE
None
Saves the settings data to the
Sensor.
MODEL
None
Re-registers the models for
registered Search inspection
items.
RESET
None
Restarts the Sensor.
TEACH
None
Executes teaching for all
applicable inspection items.
Scene control com-
mands
SCENE
S
Acquires the current scene
number.
SCENE Scene_number
S Scene_number
Changes the scene number
being used.
Data acquisition/setting
commands
POSITIONDATA
Item_number
External_reference_data_nu
mber
PD
Item_number
External_reference_data_nu
mber
Acquires data from a position
compensation item or filter
item.
POSITIONDATA
Item_number
External_reference_data_nu
mber Setting
PD
Item_number
External_reference_data_nu
mber Setting
Sets data for a position com-
pensation item or filter item.
ITEMDATA
Inspection_item_number
External_reference_data_nu
mber
ID Inspection_item_number
External_reference_data_nu
mber
Acquires the inspection item
data.
ITEMDATA
Inspection_item_number
External_reference_data_nu
mber Set_value
ID Inspection_item_number
External_reference_data_nu
mber Set_value
Sets the inspection item data. p. 371
VERGET/S
None
Acquires the version informa-
tion of the Sensor software.
VERGET/H
None
Acquires the Sensor model
information.
ERRGET
None
Acquires the latest error code
of the Sensor.
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......