Controlling Operation and Outputting Data with TCP No-protocol Communications
356
FQ2 User’s Manual
•
When Output Format Is ASCII
Set the parameters for integer digits, decimal digits, negative numbers, 0 suppression, the field separator,
and the record separator.
•
Output Format
Example: Integer digits: 5, decimal digits: 3, negative number expression:
−
, zero suppressed: none, field
separator: comma, record separator: CR
*1 Because the record separator is set to CR, only one record is output for each measurement. A blank line (CR:
delimiter) will therefore be entered after the record separator. If you do not want a blank line, set the record sepa-
rator to None.
The following range of values can be output.
−
999,999,999.9999
≤
Measured value
≤
999,999,999.9999
If the measured value is lower than
−
999,999,999.9999, then
−
999,999,999.9999 is output.
If the measured value is higher than 999,999,999.9999, then 999,999,999.9999 is output.
The following values are output if JG (Judge) is set.
OK: 0
NG:
−
1
•
When Output Format Is Binary
Set the numerical expression.
Select either fixed decimal or floating-point decimal.
•
Output Format
The measurement data multiplied by 1,000 is output continuously at 4 bytes per data. Negative numbers are
output as two’s complements.
Measured value of
data 0
,
Measured value of
data 1
,
· · ·
Measured value of
data 7
CR
The data output method, digits, and data separators can be changed as needed.
The field separator is not output unless the data continues.
Data that is output after measurement is output until the last data even after the measurement is finished. Data out-
put is not interrupted midway.
Note
1
Meas
u
red
v
al
u
e of data 0
1
2
2
1
1
2
3
3
4 5
5
6 7
6
6
6 5
6 5 CR
9
9
8
7
7
7
8
.
.
.
.
,
,
,
,
Meas
u
red
v
al
u
e
of data 1
Meas
u
red
v
al
u
e of data 7
Meas
u
red
v
al
u
e of data 2
Field separator
Record separator
*1
Delimiter
Field separator
Field separator
Field separator
CR
Note
Note
4
b
ytes
4
b
ytes
4
b
ytes
<Meas
u
red
v
al
u
e of data 0 × 1,000><Meas
u
red
v
al
u
e of data 1 × 1,000>
<Meas
u
red
v
al
u
e of data 7 × 1,000>
· · ·
CR
Delimiter
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......