Inspecting with the Sensitive Search Inspection Item
118
FQ2 User’s Manual
Measurement Data That Can Be Used for External Outputs and Calculations
The following values can be used as measurement data and output to external devices via the Ethernet or used
in calculations.
4-13 Calculations and Judgements Using Inspection Item Data: p. 155
Expression text string
Data name
Description
Data range
JG
Judgement
This is the judgement result of the
sensitive search.
−
2: No judgement (not measured),
0: Judgement is OK,
−
1: Judgement is NG,
−
13: Teaching not performed error,
−
14: Figure not registered error,
−
15: Out of range error
CR
Correlation
Correlation
0 to 100
DV
Deviation
Density deviation
0 to 221
X
Position X
This is the X coordinate of the position
where the model was found.
−
999,999,999.9999 to
999,999,999.9999
Y
Position Y
This is the Y coordinate of the position
where the model was found.
−
999,999,999.9999 to
999,999,999.9999
TH
Angle
This is the angle of the position where
the model was found.
−
180 to 180
RX
Detection X
This is the X coordinate of the detec-
tion point when the model was regis-
tered.
−
999,999,999.9999 to
999,999,999.9999
RY
Detection Y
This is the Y coordinate of the detec-
tion point when the model was regis-
tered.
−
999,999,999.9999 to
999,999,999.9999
SX
Reference position X
This is the X coordinate of the position
where the model was registered.
(This is the center of the model
region.)
−
999,999,999.9999 to
999,999,999.9999
SY
Reference position Y
This is the Y coordinate of the position
where the model was registered.
(This is the center of the model
region.)
−
999,999,999.9999 to
999,999,999.9999
ST
Reference angle
This is the angle when the model was
registered.
−
180 to 180
CT
NG sub-region
This is the number of NG sub-regions. 0 to 100
AN
Sub-region number
This is the number of the regions with
the lowest correlation.
0 to 99
ANX
Sub-region number (X)
This is the column number in the X
direction of the output region.
0
ANY
Sub-region number (Y)
This is the row number in the Y direc-
tion of the output region.
0
DX
Sub-region pos. X
This is the X coordinate of the sub-
region that was found.
−
999,999,999.9999 to
999,999,999.9999
DY
Sub-region pos. Y
This is the Y coordinate of the sub-
region that was found.
−
999,999,999.9999 to
999,999,999.9999
CRN[0] to CRN[99]
Correlation (sub-region)
This is the correlation of the sub-
region that was found.
0 to 100
DVN[0] to DVN[99]
Deviation (sub-region)
This is the density deviation of the
region that was found.
0 to 221
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......