4
Settin
g Up In
spections
Calculations and Judgements Using Inspection Item Data
FQ2 User’s Manual
155
4-13 Calculations and Judgements Using Inspection Item Data
You can set inspection item judgement results and measurement data with the Calculation menu command to
use them in basic arithmetic operations and functions. The judgement results of the calculations are reflected
in the overall judgement.
Calculation
Use the Calculation menu command to set the calculation expressions and the judgement parameters for the
calculation results.
Expression
You can get up to 32 expressions. You can also combine expressions.
You can use the following values in calculations.
• Filter item and position compensation item data (measurement data, reference values, and judgement
results)
• Inspection item data (measurement data, reference values, and judgement results)
• Constants
• Other calculation results
Judgement
Upper and lower limit values are used for the judgement of calculation results (D0 to D31). Each calculation
judgement result (J0 to J31) is turned ON if the result falls within the upper and lower limits. The OR logic of
these results will be the overall judgement result JG.
You can reflect the judgement results (JG) of the calculations in the overall judgement. (You can also set the
output parameters so that the judgement results are not reflected in the overall judgement.)
Summary of Contents for FQ2 Series
Page 1: ...User s Manual Smart Camera FQ2 Cat No Z326 E1 01A ...
Page 58: ...Setting Up Ethernet 56 FQ2 User s Manual MEMO ...
Page 90: ...Adjusting the Images That Were Taken 88 FQ2 User s Manual MEMO ...
Page 190: ...Adjusting Judgement Parameters during Operation 188 FQ2 User s Manual MEMO ...
Page 234: ...Functions Related to the System 232 FQ2 User s Manual MEMO ...
Page 404: ...Basic Troubleshooting 402 FQ2 User s Manual MEMO ...
Page 513: ...Index FQ2 User s Manual 511 Index 12 ...
Page 515: ......