![background image](http://html1.mh-extra.com/html/omron/cx-process-monitor-plus-2/cx-process-monitor-plus-2_operation-manual_744195099.webp)
84
Control Screens
Section 4-7
Changing SP
Change SP using the SP Change Up/Down Buttons.
First press the
SP
Button, select the value column, and then enter the change
using the ten-key dialog (using the mouse), or the keyboard. (The ten-key pad
is displayed when the input box is selected. To enable inputting from the ten-
key, click the
System Info.
Button in the Setup Dialog Box, and then change
the setting to enable the ten-key.
Changing MV
Change the MP using the MP Change Up/Down Buttons.
First press the
MP
Button, and then enter the change using the ten-key dialog
box (using the mouse), or the keyboard.
Remote/Local (R/L)
Switching
When the SP setting (local only, or remote/local both possible) for ITEM024
for Basic PID, Advanced PID, Indication and Setting, Ratio Setting, 2-position
ON/OFF, and 3-position ON/OFF is 1 (remote/local both possible), CAS is dis-
played.
When the
CAS
Button is red, the setting is on remote SP. When the
CAS
But-
ton is blue, the setting is on local SP. Click the
CAS
Button to switch the set-
ting.
Note
When the CX-Process Monitor Plus is set to Remote SP, A/M automatically
switches to AUTO. You cannot set Manual.
A/M Switching
When AUTO is lit red, the setting is AUTO. You can change the SP value.
When MAN is lit blue, the setting is manual. You can change MV and SP val-
ues. Select AUTO or MAN to switch.
MV Adjustment Area Details:
Basic PID (011), Advanced PID (012), Batch Flowrate Capture (014), Indication and Operation (032),
Ratio Setting (033)
Make Manual Pointer and MV open direction settings when registering the
Control Screen. Refer to
5-5-2 Overview of Screen Registration
for details.
Make output limit (ML, MH) settings using the Tuning screen. Refer to
4-8 Tun-
ing Screens
for details.
MV open direction
enabled (0%)
AUTO or
remote (CAS)
MV open direction
enabled (100%)
Manual
No Manual Pointer
Manual
Pointer
MV open direction
disabled
Output limit (ML)
Output limit (MH)
AUTO or
remote (CAS)
Manual
AUTO or remote (CAS)
Manual
AUTO or remote (CAS)
Output operation switches
Manual
Output operation switches
2-position ON/OFF (001)
3-position ON/OFF (002)
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...