![background image](http://html1.mh-extra.com/html/omron/cx-process-monitor-plus-2/cx-process-monitor-plus-2_operation-manual_744195128.webp)
113
Segment Program 2 Screens
Section 4-11
Segment Program 2 Collection Cycles and Maximum Save Times
The following table shows the Segment Program 2 Monitor Screen data col-
lection cycles and maximum save times.
Note
1.
The collection cycle is set using the CRT Builder Dialog Box (Segment Pro-
gram 2 Screen) from the Builder Window. For details on collection cycle
settings, refer to
5-5-2 Overview of Screen Registration
.
2.
Depending on the number of combined function blocks and the model of
Loop Controller that is connected, it may not be possible to collect the data
within the collection cycle that is set. If the data is displayed on a graph un-
der these conditions, the data will be updated with the same values as for
the previous collection. To remedy this situation, take measures such as
lengthening the collection cycle interval.
Segment Data Collection Starting and Stopping
When the monitored Segment Program 2 Block S1 (ITEM 013) turns ON, data
collection starts. When it turns OFF, data collection stops.
When segment data collection is started, Segment Program 2 trend files are
automatically created in binary format for each Segment Program 2 Screen.
Note
Start the CX-Process Monitor Plus before starting to run Segment Program 2.
If it is started after the CX-Process Monitor Plus, the step data may not match
the monitored program output display.
Segment Program 2 Status Display
Segment Program 2 status is displayed at the upper right of the Segment Pro-
gram 2 Monitor Screen.
There are three types of status display, as shown below.
Item
Details
Collection cycle
(See note.)
1 s, 10 s, 1 min
Maximum save time
3 days (Collection cycle: 1 s)
30 days (Collection cycle: 10 s)
180 days (Collection cycle: 1 min)
Displayed when U10 Waiting (ITEM 019) in the Segment Program 2 block turns ON.
Displayed when U2 Arrival at Final Segment (ITEM 016) in the Segment Program 2 block turns ON.
Displayed when U1 X1 Input Error (ITEM 015) in the Segment Program 2 block turns ON.
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...