CX-Process Monitor Plus
Section 1-1
1-1-6
CX-Process Monitor Plus Software Specifications
CX-Process Monitor Plus Specifications
Item
Descriptions
Product name
CX-Process Monitor Plus
Model
WS02-LCMC1-EV2
Applicable PLC-series
CS/CJ-series
Applicable Unit
Loop Control Unit Ver. 2.0 or later
Loop Control Board
Process-control CPU Unit
Loop-control CPU Unit
Applicable
computer
Personal computer
IBM PC/AT or compatible
CPU
Min. required: Pentium MMX233 MHz or faster, Recommended: Celeron
400 MHz or faster
OS
Microsoft Windows NT 4.0 (Service Pack 6a or higher), Windows 2000 Profes-
sional (Service Pack 4 or higher), Windows XP Professional (Operation is not
supported on Windows 95, 98, or ME.)
Memory
Min. required: 128 Mbytes, Recommended: 256 Mbytes or more
Hard disk drive
Min. required: 650 Mbytes of free space, Recommended: 800 Mbytes or more
of free space
Monitor
Min. required: XGA, Recommended: XGA or higher, min. 1024
×
768 dots, 256
colors
CD-ROM drive
At least one
Mouse
Recommended: Microsoft mouse or compatible pointing device
Printer
Any printer supported by Microsoft Windows
Sound board
1 board
Required software
FinsGateway (One of the following must be installed according to the commu-
nications method with the PLC.)
Serial Unit driver (Host Link)
Controller Link driver (Controller Link)
CLK (PCI) driver (Controller Link, PCI bus)
ETN_UNIT driver (Ethernet)
Connecting
method
Connection with CPU Unit
(or Serial Communications
Board/Unit)
Using Fins-
Gateway
Serial Unit
version
The computer is connected to the CPU Unit peripheral ports or
integrated RS-232C port, or RS-232C port of the Serial Com-
munications Unit. (Only a 1:1 connection is possible.)
– Connector cable:
When connecting to the CPU Unit peripheral ports: Model
CS1W-CN
@@@
(2 m, 6 m)
When connecting to the CPU Unit’s RS-232C port: Model
XW2Z
@@@
-
@
(2 m, 5 m)
– Communications protocol with PLC: Host Link (not supported
on Peripheral bus)
Connection via Controller
Link
Using Fins-
Gateway CLK
(PCI) Driver
Install the driver in a computer equipped with a Controller Link
Support Board (PCI slot) to support communications between
the computer and PLCs equipped with a Controller Link Unit.
Using Fins-
Gateway
Controller
Link driver
Install the driver in a computer equipped with a Controller Link
Support Board (ISA slot) to support communications between
the computer and PLCs equipped with a Controller Link Unit.
Connection via Ethernet
Using Fins-
Gateway
ETN_UNIT
driver
Install the FinsGateway ETN_UNIT driver on the computer on
which an Ethernet board is mounted to enable to enable com-
munications with the PLC on which the Ethernet Unit is
mounted.
Loop Control Unit/Board data specifica-
tion method
CSV tags and tags for Monitor Plus (CSV monitor tags) are set using the CX-
Process Tool. These tags are used to specify Loop Control Unit/Board data.
Offline operation functions
Prepare user configuration screens for use in the online operation screen.
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...