![background image](http://html1.mh-extra.com/html/omron/cx-process-monitor-plus-2/cx-process-monitor-plus-2_operation-manual_744195043.webp)
28
Installation
Section 2-1
2-1
Installation
Install the CX-Process Monitor Plus using the following procedure.
Note
1.
This software must be installed on an computer using Windows NT 4.0,
2000, or XP as its OS. It will not operate on Windows 95, 98, or Me.
2.
Be sure to install FinsGateway Embedded before installing CX-Process
Monitor Plus. You cannot install CX-Process Monitor Plus first.
3.
You cannot start CX-Process Monitor Plus if FinsGateway Embedded is
not installed.
4.
If connecting CX-Process online using a PLC and Host Link, you cannot
install and use CX-Process on the same computer as FinsGateway Ver-
sion 1.
New
installation
Yes
Yes
No
CX-Process Monitor
Are CX-Process
Monitor and Monitor
Plus Version 1 already
installed?
Is CX-Process
Monitor and Monitor
Plus Version 1 data to
be used with Monitor
Plus Version 2?
What is the version
of the CX-Process
Monitor and Monitor
Plus data?
Move the CX-Process Monitor Plus
Version 1 database.
Convert the CX-Process Monitor Plus
Version 1 database (using the Trend
Database Conversion Utility).
Copy the data that was converted.
Redo the Graphic Screen data settings
(if Graphic Screens are being used).
Reset to CX-Process Monitor Plus
tags all of the monitor tags set using
the CX-Process Tool.
Move the CX-Process Monitor
database.
Convert the CX-Process Monitor (using
the Trend Database Conversion Utility).
Copy the data that was converted.
Redo the Graphic Screen data settings
(if Graphic Screens are being used).
Reallocate the reset tags for CX-
Process Monitor Plus Version 2 on the
control and graphic screens.
Update
(Previous data will not
be used.)
(Screen configuration data
and trend information will
be lost.)
CX-Process Monitor
Plus Version 1
Install FinsGateway, Embedded Version.
(See sections
2-1-1
and
2-1-2
)
Uninstall the CX-Process Monitor
and Monitor Plus Version 1.
(See section
2-1-3
)
Convert CX-Process Monitor Plus Version
1 data (See section
2-1-5
)
Uninstall CX-Process Monitor Plus
Version 1. (See section
2-1-3
)
Convert the CX-Process Monitor data.
(See section
2-1-6
.)
Install CX-Process Monitor Plus Version 2. (See section
2-1-4
.)
Convert the CX-Process Monitor Plus
Version 1 data. (See section
2-1-5
.)
Convert the CX-Process Monitor data.
(See section
2-1-6
.)
Uninstall the CX-Process Monitor.
(See section
2-1-3
.)
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...