239
Reading/Writing Function Block ITEMs
Appendix A
Batch Flowrate Capture (Block Model 014)
Note
Only optional tags can be set.
ITEM
type
ITEM
Tag ITEM
Data description
Data
range
CX-Process Monitor screen (R:Read W:Write)
Over-
view
Screen
Control
Screens
Tuning
Screens
Trend
Screens
Batch
Trend
Screen
Segment
Program
2 Screen
(See
note.)
Graphic
Screens
Annun-
ciator
Screens
Alarm
Log
Screens
Contact
input
000
MT_ST
Stop block oper-
ation com-
mand(0: Cancel
stop, 1: Stop)
0 or 1
R (Color) R
(Color)
R/W
R
R
R
R
R
Accumu-
lated value
input
007
P1
PV input
0 to 9999
R
R
R
R
Accumu-
lated value
output
012
Q1
Accumulated
value (lower 4
digits)
0000 to
9999
R
R
R
R
R
013
Q2
Accumulated
value (upper 4
digits)
0000 to
9999
R
R
R
R
R
Contact
input
014
S3
Accumulation
counter reset
switch
(1: Reset)
0 or 1
R/W
R
R
R
R/W
Analog
output
016
Y1
Instantaneous
value output
0 to
320.00%
R
R
R
R
R
R
Parameter
023
SP
Local SP setting
0 to 9999
W
W
W
Contact
input/
parameter
026
R/L_SW
Remote/Local
switching
0: Local, 1:
Remote
0 or 1
R/W
R/W
R
R
R
R/W
R
Accumu-
lated
value out-
put
029
SP
Current Set
Point output
0 to 9999
R
R
R
R
R
R
032
B0
Overrun setting
(value sub-
tracted from BM)
0 to 9999
R/W
R
R
R
R/W
033
BP
Pre-batch set-
ting (value sub-
tracted from BM)
0 to 9999
R/W
R
R
R
R/W
034
B1
Flowrate limita-
tion
0 to 9999
R/W
R
R
R
R/W
Analog
output
035
SM
Batch accumu-
lated value
(lower 4 digits)
Fixed value
0000 to
9999
R
R
R
R
R
R/W
Contact
input
036
S1
Run switch
(0: Reset, 1:
Run)
0 or 1
R/W
R/W
R
R
R
R/W
R
037
S2
Control inter-
rupt switch (1:
Interrupt)
0 or 1
R/W
R/W
R
R
R
R/W
R
Contact
output
038
U1
Main batch out-
put
0 or 1
R
R
R
R
R
R/W
R
039
U2
Pre-batch output 0 or 1
R
R
R
R
R
R/W
R
Contact
input/
parameter
086
A/M_SW
SW
0: Manual, 1:
Auto
0 or 1
R/W
R/W
R
R
R
R/W
R
Parameter
089
MV
Host display of
MV
±
320.00%
R/W
R/W
R
R
R
R/W
091
MV_ABN
MV error display
0: Normal, 1:
Error
0 or 1
R
R
R
R
R
R
R
R
098
MV_IDX
MV index posi-
tion
–15 to
115.00%
R
R/W
R
R
R
R/W
099
OP_MK
Label
0 to 15
R/W
R/W
R
R
R
R/W
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...