![background image](http://html1.mh-extra.com/html/omron/cx-process-monitor-plus-2/cx-process-monitor-plus-2_operation-manual_744195134.webp)
119
Segment Program 2 Screens
Section 4-11
Note
Changing the Segment Program 2 Screen Name
If the name of a Segment Program 2 Screen is changed using the Builder
Window CRT Builder Dialog Box (Segment Program 2 Screen), Segment Pro-
gram 2 trend files created by data collection prior to the change can no longer
be referenced.
CSV File Output
Data collected using the Segment Program 2 Monitor Screen (data grouped
by date, time, or tag number) can be output in CSV (Comma Separated Val-
ues) file format either automatically or manually.
Automatic Saving
The following settings are used when configuring screens (i.e., when register-
ing Segment Program 2 Screens).
• Automatic save enable
• Save filter name and save destination folder
The CSV file is automatically saved according to these settings when seg-
ment data collection stops (when S1 turns OFF).
Manual Saving (Saving by
Using Buttons)
Use the following procedure.
1,2,3...
1.
Press the
CSV
Button in the Segment Program 2 Monitor Screen to display
the CSV export Dialog Box.
2.
Select the Segment Program 2 trend file to export.
3.
Specify a name for the CSV file and click the
OK
Button. The CSV file will
be created.
(The file can be created in a specified folder by clicking the
Browse
Button.
The default file name is “
Segment_Program_2_trend_file_name
.CSV.”)
CSV File Specifications
Segment Program 2 trend (comma) Version (carriage return)
Screen name text string (carriage return)
Output time (comma) Output date data (comma) Output time data (carriage
return) (carriage return)
Step (comma) Step time (comma) Time unit (comma) Program output value
(comma) Output value unit (comma) Wait time (comma) Time unit (comma)
Wait width (comma) Wait width unit (carriage return)
0 (comma) Step 0 output value data (carriage return)
1 (comma) Step 1 step time data (comma) Step 1 time unit data (comma)
Step 1 program output value data (comma) Step 1 output value unit data
(comma) Step 1 wait time data (comma) Step 1 wait time unit data (comma)
Step 1 wait width data (comma) Step 1 wait width unit data (carriage return)
:
(Continued to step 30.)
:
Summary of Contents for CX-Process Monitor Plus 2
Page 1: ...CX Process Monitor Plus Ver 2 Cat No W428 E1 02 SYSMAC WS02 LCMC1 EV2 OPERATION MANUAL...
Page 2: ...WS02 LCMC1 EV2 CX Process Monitor Plus Ver 2 Operation Manual Revised January 2007...
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x...
Page 15: ...xvi Application Precautions 4...
Page 41: ...26 Basic Operating Procedure Section 1 2...
Page 243: ...228 Checking Configurations Section 5 7...
Page 267: ...252 Reading Writing Function Block ITEMs Appendix A...
Page 269: ...254 Differences between Trend Screens and Batch Trend Screens Appendix B...