ISD94100 Series Technical Reference Manual
Sep 9, 2019
Page
77
of 928
Rev1.09
IS
D
9
410
0
S
ER
IE
S
T
E
C
HN
ICA
L
RE
F
E
RE
NCE
M
AN
U
AL
Bits
Description
[0]
BODEN
Brown-out Detector Enable Bit (Write Protected)
The default value is set by flash controller user configuration register CBODEN (CONFIG0
[19]).
0 = Brown-out Detector function Disabled.
1 = Brown-out Detector function Enabled.
Note 1:
The reset value of SYS_BODCTL[0] is determined by user flash configuration.
Note 2:
Brown-out detector can only work when both BODEN(SYS_BODCTL[0]) and
LVREN(SYS_BODCTL[7]) are set to 1.
Note 3:
When both BODEN(SYS_BODCTL[0]) and LVREN(SYS_BODCTL[7]) are set to 1,
NVIC BOD interrupt must be enabled before entering power down mode.
Note 4:
This bit is write protected. Refer to the SYS_REGLCTL register.