3.2 Specified Point
3-12
*2
The group axes by which the specified point is set is selected when there are two or
more group axes.
*3
Move the manipulator to the new specified point.
*4
The specified point is modified.
3.2.3
Procedure After an Alarm
If the absolute data allowable range alarm occurs, perform the followings
• Reset the alarm
• Turn Servo power on
and confirm the specified point. After the confirmation, if the PG is found to be the cause of the
alarm, perform the necessary operation, such as replacing the PG, etc.
The robot position data when turning power off and on are shown in “Power ON/OFF Position
Display”.
• Be aware of safety hazards when performing the position confirma-
tion of the specified point.
Abnormality of the PG system may be cause for alarm. The manipulator may oper-
ate in an unexpected manner, and there is a risk of damage to equipment or injury.
Refer to " 5.6 Position Data When Power is Turned ON/OFF " for details on the
“Power ON/OFF Position Display”.
S P E C I F I E D P O I N T
SPECIFIED CURRENT DIFFERENCE
R1:S
0 0 0
L
0 0 0
U
0 0 0
R
0 0 0
B
0 0 0
T
0 0 0
!Available to move to any modify specified point
R 1
S
C
L
D A T A
E D I T
D I S P L A Y
U T I L I T Y
W A R N I N G
N OT E
Summary of Contents for SK300X
Page 2: ......
Page 4: ...SK300X Manipulator Manual XRC 2001 ii MOTOMAN NOTES...
Page 7: ...INTRODUCTION MOTOMAN 1 3 SK300X Manipulator Manual XRC 2001 NOTES...
Page 21: ...viii...
Page 25: ...xii...
Page 41: ...1 7 Notes on MOTOMAN Disposal 1 16...
Page 59: ...4 3 Connection Methods 4 12...
Page 67: ...6 1 Movement of the Axes 6 4...
Page 73: ...8 2...
Page 74: ......
Page 93: ...3 3 Location 3 6...
Page 99: ...4 2 Cable Connection 4 6...
Page 103: ...5 4 Dimensions and Working Range 5 4 Fig 10 b Dimesions and Working Range YR SK300 J1...
Page 104: ...5 4 Dimensions and Working Range 5 5 Fig 10 c Dimesions and Working Range YR SK300 J2...
Page 109: ...6 2 Wrist Flange 6 4...
Page 133: ...9 2 Notes on Maintenance Procedures 9 18...
Page 136: ...11 1 S Axis Driving Unit 11 1 11 Parts List 11 1 S Axis Driving Unit...
Page 138: ...11 2 L U Axis Driving Unit 1 11 3 11 2 L U Axis Driving Unit 1...
Page 140: ...11 3 L U Axis Driving Unit 2 11 5 11 3 L U Axis Driving Unit 2...
Page 234: ...2 8 General I O Signal Assignment 2 72...
Page 270: ...4 4 Recommended Spare Parts 4 30...
Page 285: ...xiv...
Page 286: ...Setup Diagnosis...
Page 287: ......
Page 289: ...1 2...
Page 297: ...2 1 Protection Through Security Mode Settings 2 8...
Page 395: ...3 17 File Initialize 3 98...
Page 417: ...4 2 Addition of Base and Station Axis 4 22...
Page 435: ...5 6 Position Data When Power is Turned ON OFF 5 18...
Page 436: ...Hardware...
Page 437: ......
Page 447: ...6 4 Equipment Configuration 6 10...
Page 456: ...8 8 Open Phase Check 8 8...
Page 476: ...9 4 Recommended Spare Parts 9 20...
Page 477: ...Alarm Error...
Page 478: ......
Page 523: ......
Page 524: ......
Page 525: ......
Page 526: ......
Page 527: ......
Page 528: ......
Page 529: ......
Page 530: ......
Page 531: ......
Page 532: ......
Page 533: ......
Page 534: ......
Page 535: ......
Page 536: ......
Page 537: ......
Page 538: ......
Page 539: ......
Page 540: ......
Page 541: ......
Page 542: ......
Page 543: ......
Page 544: ......
Page 545: ......
Page 546: ......
Page 547: ......
Page 548: ......
Page 549: ......
Page 550: ......
Page 551: ......
Page 552: ......
Page 553: ......