1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
95
1
[Pr. PD05_Input device selection 3 (*DI3)]
Select the device to be assigned to the input signal of the CN3 connector. The connector pin numbers to be assigned are as
follows.
[Pr. PD05.0-1_Device selection]
Refer to the following for setting values.
Page 93 [Pr. PD03_Input device selection 1 (*DI1)]
■
Using touch probe function
The touch probe function can be used by setting this servo parameter to TPR1 to TPR3.
Setting this servo parameter to TPR1 to TPR3 on the MR-J5-_G triggers [AL. 037 Parameter error].
If duplicated input devices (TPR1 to TPR3) exist in [Pr. PD05], [Pr. PD38] and [Pr. PD39], [AL. 037 Parameter error] occurs.
Ex.
When TPR1 is duplicated, such as when [Pr. PD05.0] = "2Ch" (TPR1) and [Pr. PD38.0] = "2Ch" (TPR1)
Initial value
Setting range
Setting method
Ver.
00000022h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Model
Shaft
Connector pin No.
Initially assigned device
MR-J5-_G_
CN3-19
DOG
MR-J5W2-_G_
A-axis
CN3-9
DOG-A
B-axis
CN3-22
DOG-B
MR-J5W3-_G_
A-axis
CN3-9
DOG-A
B-axis
CN3-22
DOG-B
C-axis
CN3-15
DOG-C
MR-J5D1-_G_
CN3-29
DOG
MR-J5D2-_G_
A-axis
CN3-29
DOG-A
B-axis
CN3-27
DOG-B
MR-J5D3-_G_
A-axis
CN3-29
DOG-A
B-axis
CN3-27
DOG-B
C-axis
CN3-11
DOG-C
Initial value
Setting range
Ver.
22h
Refer to the text
A0