5 NETWORK PARAMETER DETAILS
5.1 Network basic parameters
217
5
[Pr. NPA08_Host name]
Select a host name.
Set a character string of up to 63 characters for the host name.
The characters that can be input as the host name are 0 to 9, A to Z, a to z, hyphen (-), period (.), colon (:), and underscore
(_).
This network parameter can be obtained with SLMP command (NodeSearch). The command is "0E30h" and subcommand is
"0000h".
This network parameter can be set with SLMP command (IPAddressSet). The command is "0E31h" and subcommand is
"0000h".
[Pr. NPA12_Communication speed]
Set the communication speed.
1: 100 Mbps
2: Network automatic setting
To enable this network parameter, cycle the power or reset the software after setting.
Details of the communication speed are as follows:
*1 Available on servo amplifiers with firmware version C0 or later.
Initial value
Setting range
Size
Ver.
0 (All NULL)
63 characters (Refer to the text.)
64 bytes
A0
Initial value
Setting range
Size
Ver.
00000002h
Refer to the text
4 bytes
B6
[Pr. PN13.0-3 Network protocol setting]
[Pr. NPA12]
Communication speed
0000h (CC-Link IE TSN) (initial value)
2 (initial value)
1 Gbps
0000h (CC-Link IE TSN) (initial value)
1
100 Mbps
0004h (CC-Link IE Field Network Basic)
2 (initial value)
100 Mbps
0004h (CC-Link IE Field Network Basic)
1
100 Mbps