240
7 FUNCTIONAL SAFETY PARAMETER DETAILS
7.4 Safety I/O device parameters group ([Pr. PSD_ _ ])
[Pr. PSD08_Output device selection DO1 (**SDO1)]
Select the device to be assigned to the output signal of the CN8-6/CN8-7 pin.
If this functional safety parameter is set incorrectly, [AL. 537 Parameter setting range error (safety sub-function)] occurs.
[Pr. PSD08.0-1_Safety output device selection DO1]
Select the device to be assigned to the output signal of the CN8-6/CN8-7 pin.
Refer to the following table for setting values.
Selecting a value other than "00" (none), "01" (STOS), "02" (SS1S), or "0A" (SBCS) on a servo amplifier other than the MR-
J5-_G_-RJ and MR-J5D_-_G_ triggers [AL. 537 Parameter setting range error (safety sub-function)].
[Pr. PSD08.2_All-axis output condition selection DO1]
0: AND output
1: OR output
For AND output, the condition becomes significant (on or off) when the A, B, and C-axes all satisfy the condition.
The device name at this time is C-_ _ _. (example: "C-STOS")
For OR output, the condition becomes significant (on or off) when any of A, B, or C-axis satisfies the condition.
The device name at this time is X-_ _ _. (example: "X-STOS")
This functional safety parameter is enabled when [Pr. PSD08.3 Output axis selection] is set to "0" (all axes) while a multi-axis
amplifier is used.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Common
Refer to the relevant detail No.
Initial value
Setting range
Ver.
00h
Refer to the text
B2
Setting value
Output device
00
None
01
STOS (STO output)
02
SS1S (SS1 output)
03
SS2S (SS2 output)
04
SLS1S (SLS1 output)
05
SLS2S (SLS2 output)
06
SLS3S (SLS3 output)
07
SLS4S (SLS4 output)
08
SSMS (SSM output)
09
SOSS (SOS output)
0A
SBCS (SBC output)
0B
SDIPS (SDIP output)
0C
SDINS (SDIN output)
0D
SLT1S (SLT1 output)
0E
SLT2S (SLT2 output)
0F
SLT3S (SLT3 output)
10
SLT4S (SLT4 output)
12
SLIS (SLI output)
Initial value
Setting range
Ver.
0h
Refer to the text
B2