1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
103
1
[Pr. PD22_Driver communication setting - Slave - Master axis 1 -
Station No. setting ( *SM1N)]
Set the station No. of master axis 1.
This servo parameter is enabled when it is set as the slave axis (when [Pr. PD15.1] is set to "1").
When "0" is set, this servo parameter is disabled.
[Pr. PD23_Driver communication setting - Slave - Master axis 1 -
Transmission and receive setting ( *SM1C)]
[Pr. PD23.1_Driver communication setting - Slave - Master axis 1 - Control slave axis
No. setting]
Set the control slave No. for master axis 1.
This servo parameter is enabled when it is set as the slave axis (when [Pr. PD15.1] is set to "1").
To set the servo amplifier as a control slave axis, set any value from "1" to "8". When "0" is set, this servo amplifier being used
will not function as a control slave axis.
Initial value
Setting range
Setting method
Ver.
0
0 to 255
Each axis
D0
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
0h to 8h
D0