140
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF85_Drive recorder - Trigger level setting 1 (DRTL1)]
Set the trigger level of trigger channel No. 1 of the drive recorder in decimal.
Set the value considering the decimal point.
For example, if setting a torque of 100.0 [%] for the trigger level, set this servo parameter to "1000" because the torque unit is
[0.1 %].
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
• [Pr. PF80.0] is set to "1" (manual setting mode) and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm
trigger)
• A digital channel is set in the first trigger of [Pr. PF84.0-1 Drive recorder - Trigger channel selection 1]
[Pr. PF86_Drive recorder - Trigger level setting 2 (DRTL2)]
Set the trigger level of trigger channel No. 2 of the drive recorder in decimal.
Set the value considering the decimal point.
For example, if setting a torque of 100.0 [%] for the trigger level, set this servo parameter to "1000" because the torque unit is
[0.1 %].
The servo parameter is disabled in the following conditions.
• [Pr. PF80.0 Drive recorder - Operation mode selection] is set to "0" (automatic setting mode)
• [Pr. PF80.0] is set to "1" (manual setting mode) and [Pr. PF82.0 Drive recorder - Trigger mode selection] is set to "0" (alarm
trigger)
• [Pr. PF82.1 Drive recorder - Trigger binding condition selection] is set to "0" (disabled)
• A digital channel is set in the second trigger of [Pr. PF84.2-3 Drive recorder - Trigger channel selection 2]
Initial value
Setting range
Setting method
Ver.
0
-2147483648 to 2147483647
Each axis
A0
Initial value
Setting range
Setting method
Ver.
0
-2147483648 to 2147483647
Each axis
A0