46
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
[Pr. PB17.2_Notch depth selection]
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB18_Low-pass filter setting (LPF)]
Set the low-pass filter.
Refer to the table below for the status of this servo parameter and the setting values of the related servo parameter.
When [Pr. PA08.0 Gain adjustment mode selection] is set to "5" (quick tuning mode), this servo parameter returns to the initial
value.
89
342
8A
339
8B
336
8C
333
8D
330
8E
327
8F
324
90
321
91
318
92
315
93
313
94
310
95
307
96
305
97
302
98
300
99
297
9A
295
9B
292
9C
290
9D
288
9E
285
9F
283
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
3141 [rad/s]
100 to 36000
Each axis
A0
[Pr. PB23.1 Low-pass filter selection]
[Pr. PB18 Low-pass filter setting]
"0" (initial value)
Automatic setting
"1"
Setting value enabled
"2"
Setting value disabled
Setting value
Frequency [Hz]