1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
59
1
[Pr. PB49_Notch shape selection 4 (NHQ4)]
Set forms of the machine resonance suppression filter 4.
[Pr. PB49.0_Machine resonance suppression filter 4 selection]
0: Disabled
1: Enabled
When this setting value is "Enabled", [Pr. PB17 Shaft resonance suppression filter] cannot be used.
[Pr. PB49.1_Notch depth selection]
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB49.2_Notch width selection]
0:
α
= 2
1:
α
= 3
2:
α
= 4
3:
α
= 5
[Pr. PB50_Machine resonance suppression filter 5 (NH5)]
Set the notch frequency of the machine resonance suppression filter 5.
When [Pr. PB51.0 Machine resonance suppression filter 5 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
4500 [Hz]
10 to 9000
Each axis
A0