1 SERVO PARAMETER DETAILS
1.9 Positioning control setting servo parameters group ([Pr. PT_ _ ])
165
1
[Pr. PT41_Function selection T-8 (TOP8)]
[Pr. PT41.0_Homing prohibition selection]
0: Disabled
1: Enabled
When "1" is set, the homing is not performed even if the start signal is turned on in the homing mode.
[Pr. PT45_Homing method (HMM)]
Set a homing method.
An attempt to execute homing with an unsupported method triggers "Homing error". At this time, homing cannot be executed.
This function corresponds to [Homing method (Obj. 6098h)].
When the object is mapped to the cyclic communication, do not write values with engineering tools because the controller
overwrites the servo parameter values written with engineering tools.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Setting method
Ver.
37
Refer to the text
Each axis
A0