124
1 SERVO PARAMETER DETAILS
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
[Pr. PF34_Machine diagnosis function selection (*MFP)]
[Pr. PF34.0_Friction failure prediction warning selection]
0: Disabled
1: Enabled (automatic threshold setting)
2: Enabled (manual threshold setting)
3: Threshold reset
When "2" is set, if the dynamic friction exceeds the set threshold, [AL. 0F7.2 Friction failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.1_Vibration failure prediction warning selection]
0: Disabled
1: Enabled (automatic threshold setting)
2: Enabled (manual threshold setting)
3: Threshold reset
When "2" is set, if the vibration level exceeds the set threshold, [AL. 0F7.1 Vibration failure prediction warning] will occur.
When "3" is set, the setting of the servo parameter will change to "1" automatically after the threshold is reset.
[Pr. PF34.2_Servo motor total travel distance failure prediction warning selection]
0: Disabled
1: Enabled
2: Servo motor total travel distance reset
When "1" is set, if the value of the servo motor total travel di [Pr. PF47 Servo motor total travel distance offset]
exceeds the value of [Pr. PF41 Failure prediction - Servo motor total travel distance], [AL. 0F7.3 Servo motor total travel
distance failure prediction warning] will occur.
When "2" is set, the setting of the servo parameter will change to "1" automatically after the servo motor total travel distance
reset.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0