7 FUNCTIONAL SAFETY PARAMETER DETAILS
7.5 Extension setting 3 parameters group ([Pr. PSL_ _ ])
243
7
[Pr. PSD31_Output device - Feedback diagnosis execution
selection (**SDOD1)]
[Pr. PSD31.0_Feedback diagnosis execution selection DO1]
Select whether to perform a diagnosis for the output signal of the CN8-6/CN8-7 pin. Normally, do not change the setting from
"1".
0: Do not perform diagnosis
1: Perform diagnosis
7.5
Extension setting 3 parameters group ([Pr. PSL_ _
])
[Pr. PSL02_Functional safety - Linear encoder resolution setting -
Numerator (**SLIM)]
Set the linear encoder resolution with [Pr. PSL02] and [Pr. PSL03 Functional safety - Linear encoder resolution setting -
Denominator].
Set a numerator in [Pr. PSL02].
This functional safety parameter is only enabled when using a linear servo motor.
Be sure to set this parameter to the same value set in [Pr. PL02 Linear encoder resolution setting - Numerator] when
executing position monitoring or speed monitoring for a linear servo motor. If this parameter is set to a non-matching value,
[AL. 537 Parameter setting range error (safety sub-function)] occurs.
[Pr. PSL03_Functional safety - Linear encoder resolution setting -
Denominator (**SLID)]
Set the linear encoder resolution with [Pr. PSL02 Functional safety - Linear encoder resolution setting - Numerator] and [Pr.
PSL03].
Set a denominator in [Pr. PSL03].
This functional safety parameter is only enabled when using a linear servo motor.
Be sure to set this parameter to the same value set in [Pr. PL03 Linear encoder resolution setting - Denominator] when
executing position monitoring or speed monitoring for a linear servo motor. If this parameter is set to a non-matching value,
[AL. 537 Parameter setting range error (safety sub-function)] occurs.
Initial value
Setting range
Setting method
Ver.
00001111h
Refer to the relevant detail No.
Common
Refer to the relevant detail No.
Initial value
Setting range
Ver.
1h
Refer to the text
B2
Initial value
Setting range
Setting method
Ver.
1000 [
μ
m]
1 to 65535
Each axis
B2
Initial value
Setting range
Setting method
Ver.
1000 [
μ
m]
1 to 65535
Each axis
B2