48
1 SERVO PARAMETER DETAILS
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
[Pr. PB23_Low-pass filter selection (VFBF)]
[Pr. PB23.0_Shaft resonance suppression filter selection]
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (enabled), the shaft resonance suppression
filter cannot be used.
[Pr. PB23.1_Low-pass filter selection]
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "5" (quick tuning mode) is selected in [Pr. PA08.0 Gain adjustment mode selection], this servo parameter is set to "1"
(manual setting).
[Pr. PB23.3_Shaft resonance suppression filter 2 selection]
0: Disabled
1: Automatic setting
Initial value
Setting range
Setting method
Ver.
00001000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Initial value
Setting range
Ver.
1h
Refer to the text
A0