5 NETWORK PARAMETER DETAILS
5.2 User authentication parameters
219
5
[Pr. NPB05_Authorization level No.1]
Set the authorization level for the user (No.1).
Refer to the following table for details.
*1 Available on servo amplifiers with firmware version B2 or later.
[Pr. NPB06_Password No.1]
Set the password to use when accessing the FTP server function of the servo amplifier.
Set the password in accordance with the following restrictions.
[Pr. NPB07_User name No.2]
Set the user name (No.2) to use when accessing the FTP server function of the servo amplifier.
Page 218 [Pr. NPB04_User name No.1]
[Pr. NPB08_Authorization level No.2]
Set the authorization level for the user (No.2).
Page 219 [Pr. NPB05_Authorization level No.1]
Initial value
Setting range
Size
Ver.
00000001h
Refer to the text
4 bytes
A5
Network parameter No.
Setting digit (BIN)
Description
[Pr. NPB05.0]
_ _ _ x
Firmware update permission selection
0: Prohibited
1: Permitted
When "1" (permitted) is set, firmware updates can be performed via the FTP server
function.
_ _ x _
For manufacturer setting
_ x _ _
Drive recorder data readout permission selection
0: Prohibited
1: Permitted
When "1" (permitted) is set, readout of the recorded data in the drive recorder can be
performed via the FTP server function.
x _ _ _
For manufacturer setting
[Pr. NPB05.1]
[Pr. NPB05.2]
[Pr. NPB05.3]
[Pr. NPB05.4]
[Pr. NPB05.5]
[Pr. NPB05.6]
[Pr. NPB05.7]
For manufacturer setting
For manufacturer setting
Initial value
Setting range
Size
Ver.
user
A5
Number of characters
Type of characters
4 to 32
• Single-byte letters (uppercase)
• Single-byte letters (lowercase)
• Single-byte numeric characters
• Special characters
"Special characters" refers to the following characters: ` ~ ! @ # $ % ^ & * ( ) _ + - = { } | ¥ : " ; ' < > ? , . / [ ] (additionally, a
single-byte space can be used).
Initial value
Setting range
Size
Ver.
0 (All NULL)
32 characters
36 bytes
A5
Initial value
Setting range
Size
Ver.
00000000h
Refer to the text
4 bytes
A5