5 NETWORK PARAMETER DETAILS
5.2 User authentication parameters
5.2
User authentication parameters
[Pr. NPB01_User authentication and authorization setting]
Set the connection method to use for setting the user authentication parameter.
To enable this network parameter, cycle the power or reset the software after setting.
When this network parameter is set to "1" (USB only), the user authentication parameter cannot be rewritten via the
parameter automatic setting.
[Pr. NPB04_User name No.1]
Set the user name to use when accessing the FTP server function of the servo amplifier.
Set the user name in accordance with the following restrictions. If a blank (0 character) user name is set, that account will be
disabled.
If the set user name is identical to an existing account, password and authorization level parameters linked to said user name
may be disabled. Ensure that no duplicate user names are set.
Initial value
Setting range
Size
Ver.
00000000h
Refer to the text
4 bytes
A5
Setting value
Authorization
Description
0
Full access possible
The user authentication parameter can be set via either a USB or Ethernet
connection.
1
USB only
The user authentication parameter can only be set via a USB connection.
Initial value
Setting range
Size
Ver.
user
32 characters
36 bytes
A5
Number of characters
Type of characters
1 to 32
• Single-byte letters (uppercase)
• Single-byte letters (lowercase)
• Single-byte numeric characters