182
1 SERVO PARAMETER DETAILS
1.11 Positioning extension setting servo parameters group ([Pr. PV_ _ ])
[Pr. PV23_Speed unit conversion - Electronic gear numerator
(*VCMX)]
Set the electric gear numerator for converting the speed (command unit/s) into a value in speed units.
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1".
Setting a value other than "1" on the MR-J5W3-_G_ triggers [AL. 037 Parameter error].
[Pr. PV24_Speed unit conversion - Electronic gear denominator
(*VCDV)]
Set the electric gear denominator for converting the speed command (command unit/s) into a value in speed units.
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1".
Setting a value other than "1" on the MR-J5W3-_G_ triggers [AL. 037 Parameter error].
[Pr. PV25_Acceleration unit conversion - Electronic gear
numerator (*ACMX)]
Set the electric gear numerator for converting the acceleration (command unit/s
2
) into a value in acceleration/deceleration
units.
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1".
Setting a value other than "1" on the MR-J5W3-_G_ triggers [AL. 037 Parameter error].
[Pr. PV26_Acceleration unit conversion - Electronic gear
denominator (*ACDV)]
Set the electric gear denominator for converting the acceleration (command unit/s
2
) into a value in acceleration/deceleration
units.
This function is enabled when [Pr. PT01.1 Speed/acceleration/deceleration unit selection] is set to "1".
Setting a value other than "1" on the MR-J5W3-_G_ triggers [AL. 037 Parameter error].
Initial value
Setting range
Setting method
Ver.
1
1 to 1024
Each axis
A5
Initial value
Setting range
Setting method
Ver.
1
1 to 256
Each axis
A5
Initial value
Setting range
Setting method
Ver.
1
1 to 1024
Each axis
A5
Initial value
Setting range
Setting method
Ver.
1
1 to 256
Each axis
A5