92
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
1.5
I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD01_Input signal automatic ON selection 1 (*DIA1)]
[Pr. PD01.0_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.1_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.2_Input signal automatic ON selection]
Select input devices that turn on automatically.
[Pr. PD01.3_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.4_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.5_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.6_For manufacturer setting]
This servo parameter is for manufacturer setting.
[Pr. PD01.7_For manufacturer setting]
This servo parameter is for manufacturer setting.
Initial value
Setting range
Setting method
Ver.
00000000h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
0h
Refer to the text
A0
Setting digit (BIN)
Functions
_ _ _ x
_ _ x _
_ x _ _
Forward rotation stroke end (LSP)
0: Use for an external input signal
1: Automatic on
x _ _ _
Reverse rotation stroke end (LSN)
0: Use for an external input signal
1: Automatic on