1 SERVO PARAMETER DETAILS
1.6 Extension setting 2 servo parameters group ([Pr. PE_ _ ])
113
1
[Pr. PE03_Fully closed loop control function selection 2 (*FCT2)]
[Pr. PE03.0_Fully closed loop control error - Detection function selection]
0: Disabled
1: Speed deviation error detection
2: Position deviation error detection
3: Speed deviation error detection and position deviation error detection
Refer to the following table for the combination with [Pr. PE03.1 Position deviation error - Detection method selection].
: Error detection enabled
: Error detection disabled
[Pr. PE03.1_Position deviation error - Detection method selection]
0: Continuous detection
1: Detection only at stop (An error is detected if the command is "0".)
2: Detection only at stop 2 (An error is detected during servo-off or if the command is "0" while in servo-on state.)
Refer to the following table for the combination with [Pr. PE03.0 Fully closed loop control error - Detection function selection].
Page 113 [Pr. PE03.0_Fully closed loop control error - Detection function selection]
[Pr. PE03.3_Fully closed loop control error - Reset selection]
0: Reset disabled (reset by cycling the power or software reset)
1: Reset enabled
Initial value
Setting range
Setting method
Ver.
00000003h
Refer to the relevant detail No.
Each axis
Refer to the relevant detail No.
Initial value
Setting range
Ver.
3h
Refer to the text
A5
Setting value
Speed deviation error
Position deviation error
In servo-on state
In servo-off state
[Pr. PE03.1]
[Pr. PE03.0]
With commands
No commands (= 0)
0
0
0
1
0
2
0
3
1
0
1
1
1
2
1
3
2
0
2
1
2
2
2
3
Initial value
Setting range
Ver.
0h
Refer to the text
A5
Initial value
Setting range
Ver.
0h
Refer to the text
A5