16
1 SERVO PARAMETER DETAILS
1.2 Basic setting servo parameters group ([Pr. PA_ _ ])
[Pr. PA01.7_High-speed mode selection]
When using the servo amplifier in the motion mode (high-speed), set "1" (enabled).
Setting "1" on the MR-J5W_-_G triggers [AL. 037 Parameter error].
0: Disabled
1: Enabled
When this servo parameter is set to "1" and other servo parameters are set as follows, [AL. 037 Parameter error] occurs.
• [Pr. PA01.0 Control mode selection] = "6" (positioning mode (point table method))
• [Pr. PA01.4 Fully closed loop operation mode selection] = "1" (enabled (fully closed loop control mode))
• [Pr. PA22.3 Scale measurement function selection] = "1" (use with absolute position detection system)
• [Pr. PA22.3 Scale measurement function selection] = "2" (use with incremental system)
• [Pr. PT01.1 Speed/acceleration/deceleration unit selection] = "1" (command unit/s)
• [Pr. PT01.2 Unit for position data] = "2" (degree)
• [Pr. PT02.7 Internal position command - Process speed selection] = "1" (high-speed)
• [Pr. PD15.0 Master axis operation selection] = "1" (enabled (set this servo amplifier for the master axis.))
• [Pr. PD15.1 Slave axis operation selection] = "1" (enabled (set this servo amplifier for the slave axis.))
• [Pr. PN03.1 CC-Link IE TSN Class setting] = "1" (Class A ver. 2.0)
When this servo parameter is set to "1" and the control mode is set to the profile position mode (pp), profile velocity mode (pv),
or profile torque mode (tq), [AL. 19E Network warning 2] occurs.
Initial value
Setting range
Ver.
0h
Refer to the text
A6