96
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
[Pr. PD05.4_Input axis selection 3]
For a multi-axis servo amplifier, set which axis will use the input device that was assigned in [Pr. PD05.0-1 Device selection].
When this servo parameter is "0h", only the axis to which the device is assigned by [Pr. PD05.0-1] is automatically set to be
enabled.
When A-axis selection is enabled, the device name is _ _ _-A. (Example: TPR1-A)
When B-axis selection is enabled, the device name is _ _ _-B. (Example: TPR1-B)
When C-axis selection is enabled, the device name is _ _ _-C. (Example: TPR1-C)
When multiple axes are enabled with this servo parameter, the input device signal is enabled for multiple axes simultaneously.
For example, when [Pr. PD05.4] = "5h" (A and C-axes enabled) and [Pr. PD05.0] = "2Ch" (TPR1) are set for the A-axis, TPR1-
A and TPR1-C are enabled with the input signal of CN3-9 pin.
In the following cases, [AL. 037 Parameter error] occurs.
• When other than "0h" is set for a 1-axis servo amplifier
• When C-axis selection is enabled on the MR-J5W2-G_ or MR-J5D2-_G_
• When this servo parameter is set to a value other than "0h" while the input device is set to other than TPR1, TPR2, or TPR3
• When duplicated input devices exist
Page 96 Example of duplicated settings
■
Example of duplicated settings
When TPR1-B is duplicated, such as when for the A axis, [Pr. PD05.4] = "3h" (A and B axes enabled) and [Pr. PD05.0] =
"2Ch" (TPR1); and for the B axis, [Pr. PD05.4] = "0h" (automatic setting: B axis enabled) and [Pr. PD05.0] = "2Ch" (TPR1)
Initial value
Setting range
Ver.
0h
Refer to the text
A5
Servo parameter number
Setting digit (BIN)
Setting details
[Pr. PD05.4]
_ _ _ x
A-axis selection
0: Disabled
1: Enabled
_ _ x _
B-axis selection
0: Disabled
1: Enabled
_ x _ _
C-axis selection
0: Disabled
1: Enabled