3.4.3 General I/O(I/O)
(Option)
There
’
s option for general I/O that is input 16 points and output 12 points due to control each
sensors, switches, magnet valves and indicator lights.
【I/O connector】 General I/O(I/O)
(Option)
Connector type : 10236-0200 (3M)
Adaptive connector(Ex.) : 10136-3000PE (3M)
【Option cable(2m)
】
Type
: DS100-IO-2 (MISUMI Type: MSGP2)
【I/O pin assign】
Pin No.
Signal name
I/O
Function
1
In_00
I
General input00
2
In_01
I
General input01
3
In_02
I
General input02
4
In_03
I
General input03
5
In_04
I
General input04
6
In_05
I
General input05
7
In_06
I
General input06
8
In_07
I
General input07
9
In_08
I
General input08
10
In_09
I
General input09
11
In_10
I
General input10
12
In_11
I
General input11
13
In_12
I
General input12
14
In_13
I
General input13
15
In_14
I
General input14
16
In_15
I
General input15
17
+COM2
I
In_00~In_15 for insulation power on
18
+COM3
I
OUT_00~OUT_11
for insulation power on
19
Out_00
O
General output00
20
Out_01
O
General output01
21
Out_02
O
General output02
22
Out_03
O
General output03
23
Out_04
O
General output04
24
Out_05
O
General output05
25
Out_06
O
General output06
26
Out_07
O
General output07
27
Out_08
O
General output08
28
Out_09
O
General output09
29
Out_10
O
General output10
30
Out_11
O
General output11
31
-COM3
-
Out_00~Out_11
for insulation power ground
32
-COM3
-
Out_00~Out_11
for insulation power ground
33
DC+24V
O
Service power (DC24V,max 400mA)
34
0V
O
35
NC
-
Non-connected
36
NC
-
Non-connected
Input ON current is 5mA/point、Output drive current is 60mA/point(Total
under 500mA)
DC+24V power, COM2 and COM are each insulated.