107
vi.
Confirn Save location and its name then click [Save].
Parameter file is saved in PC and selected parameter is forwarded to DS102/112.
※ spf is automatically added as extension.
4.2.3 Jog driving
Move each stages to any optional location.
<Basic operation>
i.
[Action]→[Jog] on main menu then screen below appears.
①
Axis
②
Unit
③
Current location
④
Move to +(CW)direction
⑤
Move to -(CCW)direction
⑥
Limited detection of +(CW)direction (Green:Non-detection, Red:Detection)
Double click sets up limit of software(Yellow:Detection)
⑦
Limited detection of -(CCW)direction(Green:Non-detection, Red : Detection)
Double click sets up limit of software(Yellow:Detection)
⑧
Display set value of step drive and position drive
⑨
Display speed(unit:pps fixed)
(Direct input on double click)
⑩
Speed value up(Until max speed by parameter set up)
⑪
Speed value down
ii.
Continue、Step、Position、Origin Select and click any key.
Continue: While pushing +, -, stage moves. Once released button, stage stops on parameters
set up (Fast stop or Slow stop).
Step : Once pushing +, -, stage moves by setted movement value.
When you change movement value, double click ⑧, input movement value directly.
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑪
⑩
Summary of Contents for DS102MS