73
Default setting:[SD:Operate smooth drive]
•
When operate smooth drive function、set [SD]side.(Initialization)
•
When no operate smooth drive function, set [OFF]side.
・Smooth drive function will not work when set over 10 divide division number.
Might be ignored to set[SD].(Same as[OFF]operation)
3.7 Units setting function
No need difficulty change from pulse to actual displacement.
Units setting must be first for each setting parameter. Follow the below.
① Units setting(pulse, μm, mm, deg, mrad)
②
Set 1 pulse displacement at the full step(Basic resolution)set.
③
Set the division number(1/1~1/250)
④
1pulse displacement(Automatically calculated from ①~③)
Example) In case of set the stage:KXC06020-G(1μm/pulse)to mm.
Units:mm
1 pulse displacement at the full step:0.001(mm)
Division number:1/20
1pulse displacement:0.00005(mm)
※
After setting, can use operate the setting units for all position data (except speed table).
※
In case of Sine Motion Stage(KRB04017, KRB06011, KGB07), can use only
“
PULSE
”
as
unit setting.
Smooth drive changing-over switch