152
<Ex.: Response Data>
SURUGA, DS102, 0, VER1.00
※In case of DS112,
“
DS102
”
is returned too.
4.3.5.12 General I/O Command
(1) IN00?~IN47?
Status Request Command for General I/O Request 1/bit
<Response Data>
Content
0
Input OFF
1
Input ON
(2) INP0?~INP2?
Status Request Command for General Input. Request Input 16points of each controller(LinkID0~2)
all at once.
<Response Data> is 0~65535.
<Response Data>
Contents
0
All of 16 points OFF
65535
All of 16 points ON
(3) OUT□_<Data>
Control Command of General Output.(0~35) Set 1/bit
□:00~35.
<Setting Data>
Content
0
Output OFF
1
Output ON
(4) OUTP□_<Data>
Control Command of General Output. Request Output 12points of each controller (LinkID0~2)all at
once.
□:0~2、<Response Data> is 0~4095.
<Response Data>
Content
0
All of 12 points output OFF
4095
All of 12 points output ON
(5) OUTP0?~OUTP2?
Status Request Command for General Output. Request Output 12points of each controller (LinkID
0~2) all at once.
<Response Data> is 0~4095.
<Response Data>
Content
0
All of 12 points during output OFF
4095
All of 12 points during output ON
Summary of Contents for DS102MS