95
⑨Limit Sensor(Limit Sensor Logic Setting)
Set up each axis Limit Sensor Logic Setting.
When select the
“
Limit Sensor
”
, to be Limit Sensor Logic setting screen. Display the cursor on left
lateral of setting axis
Move cursor to the left-lateral of axis that set with ↑,↓ key.
※Return to parameter selection screen with ESC key
After axis selected, press Enter key, display the cursor on left-lateral, and then input the setting data
with ↑、↓key.
After setting finished, press Enter key, be moved the cursor on left-lateral and input any other axis
※During input the setting data, press ESC key), might be return to select the setting axis without
input setting data.
⑩Origin(Origin Sensor Logic Setting)
Set up each axis Origin Sensor Logic Setting.
When select the
“
Origin
”
, to be Origin Sensor Logic setting screen. Display the cursor on left lateral of
setting axis.
Move cursor to the left-lateral of axis that set with ↑,↓ key.
※Return to parameter selection screen with ESC key.
After axis selected, press Enter key, display the cursor on left-lateral of setting data, and then input
the setting data with ↑、↓key.
After setting finished, press Enter key, be moved the cursor on left-lateral of axis and input any other
axis.
※During input the setting data, press ESC key, might be return to select the setting axis without
input setting data.
LS X B
Y
B
Parametor
Axis
Setting data
Cursol position for selected axis
Cursol position for input data
OR X B
Y
B
Parametor
Axis
Setting data
Cursol position for selected axis
Cursol position for input data
Summary of Contents for DS102MS
Page 166: ...166...