149
(7) LIMIT?
Status Request Command for Mechanical Limit Detection for each axis.
<Response Data>
Content
0
Mechanical Limit is not detected
1
Detecting Mechanical Limit in the CW direction
2
Detecting Mechanical Limit in the CCW direction
3
Detecting Mechanical Limit in the CW & CCW direction
(8) MOTION?
Status Request Command for axis in motion.
<Response Data>
Content
0
At Halt
1
In Motion
※
This is the same as Bit7 of Status Binary1? (See (12))
(9) ORiGin?
Status Request Command for Origin Detection of each axis.
<Response Data>
Content
0
Origin Return is not in process
1
Origin Return has been completed and Mechanical Origin has been
detected. At halt
※
This is the same as Bit5 of Status Binary1? (See (12))
(10) READY?
Status Request Command for availability of Axis Selection
<Response Data>
Content
0
Axis NOT loaded with driver.
1
Axis loaded with driver
※
This is the same as Bit1 of Status Binary3? (See (14))
(11) SoftLIMIT?
Status Request Command for Software Limit of each axis
<Response Data>
Content
0
Software Limit is not detected
1
Detecting Software Limit in the CW direction
2
Detecting Software Limit in the CCW direction
(12) StatusBinary1?
Status Request Command for One byte Binary Code for each axis.
※
This binary code is output as ASCII code which is converted from the numbers between 0
~255)
Summary of Contents for DS102MS