64
3.4 External Interface
3.4.1 Link connection(Link)
In case of controlled over 3 axes, can be operated max.6 axes operations connected with original
link cable (DS100-LINK2-0.5 (MISUMI Type: MSLINK2-0.5) or DS100-LINK3-0.5 (MISUMI Type:
MSLINK3-0.5) between 2 units or 3 units of DS102/DS112. (MISUMI Type:
MSCTL102/MSCTL112)
【Link connector】
Connector type
: S10B-PADSS-1(LF)(SN) (JST)
Matched plug
: PADP-10V-1-S(LF)(SN) (JST)
Conformance contact : SPH-002T-P0.5L (JST)
Pin No.
Signal
I/O
Function
1
T (+)
I/O
Transmitted and received data
(+)
2
T (-)
I/O
Transmitted and received data
(-)
3
GND
-
Ground
4
NC
-
Non connected
5
T (+)
I/O
Transmitted and received data
(+)
6
T (-)
I/O
Transmitted and received data
(-)
7
GND
-
Ground
8
NC
-
Non connected
9
GND
-
Ground
10
FG
-
Frame ground
※If use link function, need to set the ID number with DIP switch.
【Set the DIP switch】
Set third bit and forth bit of SW1
● Set link number
3
4
Link number
OFF
OFF
0(Default)
ON
OFF
1
OFF
ON
2
ON
ON
※Factory-setting is OFF.
※
Please power on in the order Link number 2,→1→0
In case of can
’
t be powered on in turn because of included system, please power on 3 units
at the same time.
1
2
3
4
5
6
ON
7
8
SW1
Summary of Contents for DS102MS