DTC B266E [POWER LIFTGATE (PLG) SYSTEM]
DTC B266E - DETECTION CONDITION POSSIBLE CAUSE CHART
1
z
Disconnect the PLG control module
connector.
z
Disconnect the PLG drive unit connector.
z
Inspect the wiring harness between PLG
control module terminal 2L and PLG drive
unit terminal J for an open circuit/short
circuit to the power supply system/short
circuit to the ground system.
z
Is the wiring harness normal?
Yes
(See
POWER LIFTGATE (PLG)
DRIVE UNIT
REMOVAL/INSTALLATION
.)
Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.
2
VERIFY CORRECTION COMPLETED
z
Reconnect the disconnected connector.
z
Clear the DTC.
z
Operate the PLG system.
z
Is DTC B266C stored?
Yes
Replace the PLG control module.
(See
POWER LIFTGATE (PLG)
DRIVE UNIT
REMOVAL/INSTALLATION
.)
No
DTC troubleshooting completed.
DTC B266E
Rotation sensor malfunction
DETECTION
CONDITION
The PLG operation direction (open/close) and the PLG motor rotation direction from
the rotation sensor do not correspond.
POSSIBLE CAUSE
z
PLG arm malfunction
z
PLG slider malfunction
z
Torque cable malfunction
z
Reverse connection of the PLG motor
z
PLG drive unit (rotation sensor) malfunction
z
PLG control module malfunction