DIAGNOSTIC PROCEDURE
DTC B2701 - DIAGNOSTIC PROCEDURE
CONDITION
POSSIBLE CAUSE
z
Short to GND in wiring harness between PLG control module terminal 3B and
PLG touch sensor (LH) terminal B
z
PLG touch sensor (LH) malfunction
z
Obstructions in the detection part
z
PLG control module malfunction
STEP
INSPECTION
ACTION
1
INSPECT PLG TOUCH SENSOR (LH)
z
Inspect the PLG touch sensor (LH).
(See
POWER LIFTGATE (PLG)
TOUCH SENSOR INSPECTION
.)
z
Is the touch sensor normal?
Yes Go to the next step.
No
Replace the PLG touch sensor (LH).
(See
POWER LIFTGATE (PLG) TOUCH
SENSOR REMOVAL/INSTALLATION
.)
Go to Step 3.
2
INSPECT WIRING HARNESS BETWEEN
PLG CONTROL MODULE AND PLG
TOUCH SENSOR (LH)
z
Inspect the wiring harness between PLG
control module terminal 3B and PLG
touch sensor (LH) terminal B for a short
circuit to ground system.
Yes Go to the next step.
No
Repair or replace the wiring harness.
Go to the next step.