134
Appendix F: The breakout board
Routing one Matrox Iris GT auxiliary output signal to the Matrox
Iris GT trigger signal
You can route Matrox Iris GT auxiliary output signal 4
(AUX(STB)_OPENC_OUT4) to the Matrox Iris GT trigger signal
(TRIG_O), using the output-to-trigger bypass switch box (SW6). To
do so, perform the following:
1. Connect the power and the digital I/O signals of your Matrox Iris GT to the
breakout board by following the steps in the
connecting its I/O signals to the breakout board
2. Turn on output-to-trigger bypass switch 1 (SW6[1]).
❖
Note that if you route auxiliary output signal 4 (AUX(STB)_OPENC_OUT4)
to the trigger signal (TRIG_), you cannot also route it to the first
Matrox Iris GT auxiliary input signal (AUX(USER)_O).
In addition, if you route auxiliary output signal 4 (AUX(STB)_OPENC_OUT4)
to auxiliary input signal 0 (AUX(USER)_O), you cannot also
generate a trigger signal using the TRIG+ button on the breakout board.
3. Turn on output-to-trigger bypass switch 2 (SW6[2]). This grounds the Matrox
Iris GT TRIG_OPTO_IN- signal.
For more information on the output-to-trigger bypass switch box (SW6), see
Output-to-trigger bypass switch box
4. Turn on output pull-up resistor switch 1 (SW7[1]).
For more information on the output pull-up resistor switch box (SW7), see the
Summary of Contents for Iris GT MIL
Page 12: ......
Page 28: ...28 Chapter 2 Powering and connecting to your Matrox Iris GT...
Page 40: ...40 Chapter 3 Configuring your Matrox Iris GT to work on a network...
Page 48: ...48 Chapter 4 Configuring your Matrox Iris GT to work with your computer directly...
Page 58: ...58 Chapter 5 Accessing Matrox Iris GT...
Page 88: ...88 Appendix A Glossary...
Page 152: ...152 Appendix F The breakout board...
Page 158: ...158 Appendix G Reading the LEDs...
Page 238: ...238 Appendix I Matrox Iris portal website details...
Page 250: ......
Page 256: ......