110
Appendix D: Using the I/O signals and controlled- current output of Matrox Iris GT
Connecting to an NPN-compatible PLC device
To connect your Matrox Iris GT to a NPN-compatible PLC device, connect the
ground of the NPN-compatible PLC device and the ground of your Matrox
Iris GT to a common ground. In addition, an auxiliary output signal of your
Matrox Iris GT must be connected to the device’s sinking input.
The NPN-compatible PLC device provides its own power source. When the
Matrox Iris GT output signal is "on" the NPN-compatible PLC device connects
to the ground and completes the circuit.
+24V
max.
+V
GND
NPN-
compatible
device
PLC
AUX(USER)_OPENC_OUT0
1
Matrox Iris GT
digital I/O and
power connector
GND
Power
source
In 0
1
Note that the output can
sink up to 100 mA.