Table 5. System pulse LEDs
LED
Description
Action
FPGA heartbeat
Power-on and power-off
sequencing
1. If the LED blinks at 1 Hz, it is functioning
properly and no action is necessary.
2. If the LED is not blinking, (trained technician
only) replace the system board.
IMM heartbeat
IMM2.1 heartbeat boot process
The following steps describe the different stages
of the IMM2.1 heartbeat sequencing process.
1. When this LED is blinking fast
(approximately 4 Hz), this indicates
that the IMM2.1 code is in the loading
process.
2. When this LED goes off momentarily, this
indicates that the IMM2.1 code has loaded
completely.
3. When this LED goes off momentarily and
then starts blinking slowing (approximately
1 Hz), this indicates that IMM2.1 is fully
operational. You can now press the
power-control button to power on the
server.
4. If this LED does not blink within 30 seconds
of connecting a power source to the server,
(trained technician only) replace the system
board.
PCI riser-card LEDs
Use this information to view PCI riser-card LEDs.
63
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......