System - Other
SNMP Trap ID
CIM Information
Prefix:
PLAT
ID:
0170
User Response
No action; information only.
•
806f0313-1701ffff : A software NMI has occurred on system [ComputerSystemElementName].
(NMI State)
This message is for the use case when an implementation has detected a Software NMI.
May also be shown as 806f03131701ffff or 0x806f03131701ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix:
PLAT
ID:
0228
User Response
1.
Check the device driver.
2.
Reinstall the device driver.
3. Update all device drivers to the latest level.
4. Update the firmware (UEFI and IMM).
•
806f0323-2101ffff : Power cycle of system [ComputerSystemElementName] initiated by watchdog
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Power Cycle by Watchdog
occurred.
May also be shown as 806f03232101ffff or 0x806f03232101ffff
Severity
Info
572
Lenovo System x3550 M5 Installation and Service Guide
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......