Table 47. Events that automatically notify Support (continued)
Event ID
Message String
Automatically
Notify Support
806f010d-0404ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 4)
Yes
806f010d-0405ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 5)
Yes
806f010d-0406ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 6)
Yes
806f010d-0407ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 7)
Yes
806f010d-0408ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 8)
Yes
806f010d-0409ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 9)
Yes
806f010d-040affff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 10)
Yes
806f010d-040bffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 11)
Yes
806f010d-040cffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 12)
Yes
806f010d-040dffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Drive 13)
Yes
806f010d-0410ffff
The Drive [StorageVolumeElementName] has been
disabled due to a detected fault. (Ext Drive)
Yes
806f011b-0701ffff
The connector [PhysicalConnectorElementName] has
encountered a configuration error. (Front USB)
Yes
806f011b-0c01ffff
The connector [PhysicalConnectorElementName] has
encountered a configuration error. (FP LCD Cable)
Yes
806f0207-0301ffff
[ProcessorElementName] has Failed with FRB1/BIST
condition. (CPU 1)
Yes
806f0207-0302ffff
[ProcessorElementName] has Failed with FRB1/BIST
condition. (CPU 2)
Yes
806f0207-2584ffff
[ProcessorElementName] has Failed with FRB1/BIST
condition. (All CPUs)
Yes
806f020d-0400ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 0)
Yes
806f020d-0401ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 1)
Yes
806f020d-0402ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 2)
Yes
806f020d-0403ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 3)
Yes
806f020d-0404ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 4)
Yes
806f020d-0405ffff
Failure Predicted on drive [StorageVolumeElementName]
for array [ComputerSystemElementName]. (Drive 5)
Yes
Appendix A. Integrated management module 2.1 (IMM2.1) error messages
289
Summary of Contents for System x3550 M5
Page 1: ...Lenovo System x3550 M5 Installation and Service Guide Machine Type 8869 ...
Page 6: ...iv Lenovo System x3550 M5 Installation and Service Guide ...
Page 66: ...52 Lenovo System x3550 M5 Installation and Service Guide ...
Page 298: ...284 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1120: ...1106 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1124: ...1110 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1132: ...Taiwan BSMI RoHS declaration 1118 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1134: ...1120 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1142: ...1128 Lenovo System x3550 M5 Installation and Service Guide ...
Page 1143: ......
Page 1144: ......